OVERVIEW

Introducing M130

M130 is a multi-purpose gateway and controller. The M130 OpenECU™ is designed for applications that require 4 CAN/CAN-FD channels and a small controller.

Intended applications include CAN-to-CAN message forwarding, LIN-to-CAN message translation, and sensor-to-CAN data broadcasting. The M130 can whitelist specific IDs to shield one CAN bus from unwanted CAN messages on a different bus, for data protection purposes. The M130 can also be used to modify the CAN messages from one bus before transmitting them on the other bus. Using the two LIN channels and the six analog inputs, the M130 can also broadcast smart sensor data to any of its four CAN busses.

M130 CAN Gateway ECU

M130 CAN Gateway ECU

Capabilities

  • Advanced 32-Bit NXP Microprocessor
    • SPC5746B
    • 80 MHz
    • Up to 3MB code space
    • Up to 256kB RAM space
    • Up to 256kB Calibration space
  • 4 high speed CAN 2.0B/ CAN-FD  channels
  • Wake on CAN (CANA)
  • 2 LIN channels
  • Ignition Input
  • Total of 6 Analog/Digital inputs
  • 2 RTD capable analog inputs
  • Software configurable delayed power off
  • 2 Analog voltage output channels
  • 1 5V 200mA sensor power supply output

Some of the Possible Applications

  • CAN Gateway Module
  • CAN to LIN Gateway
  • CAN I/O Expansion Box
  • Smart Relay Driver
  • Embedded System Control and Supervisor
  • Alternative Fuel System Controller

Hardware Specifications1

Communications
CAN-FD 4x
LIN (master)2 2x
Inputs
Ignition 1x
Analog 6x
Outputs
500mA LSD 6x
2A LSD 4x
5V Sensor Power Supply 1x
0-5V Analog ±10mA 2x
Electrical
Output Protection Short to Battery, Ground
Battery Input Protection Overvoltage, Reverse Voltage
Operating Voltage 8V to 32V
Survive Voltage -28V to 36V
Other
Program Status LED drive 1x
Reprogramming Enable In 1x @18V
Electromagnetic Compatibility (Targeted)
Conducted Emissions CISPR25 Class 2
Radiated Emissions CISPR25 Class 2
Immunity ISO 11452-4
Conducted Transients ISO 7637-2
ESD SAE J1113-13
Physical
Dimensions 138 x 130 x 42 mm (L x W x H)
Material PPA GF33
Connectors 2 x 20 pin (Molex MX150)
Vibration ISO 16750-3 Test VII
Environmental Protection IP67 – sealed
Operating Temp -40°C to 85°C

1For full details please refer to the full M130 Technical Specification

2LIN slave mode on 1 channel can be offered as a population change option

BLOCK DIAGRAM

DOWNLOADS

MODULE COMPARISON